
English RAIS - manual for RAIS 500
18
PRELEMINARY
Mounting distance for brick wall / firewall
It is recommended to knock out the 3
areas - prepared for heat transfer - out.
Min. 300 mm
Distance to combustible material
min. 200 mm (e.g. side wall)
Distance to furniture
min. 900 mm
Min. 100 mm
Recommended min convection
area below the stove : 500 cm²
(may be distributed)
To guide the hot air out of the
gratings, we recommends to
install a non-flammable plate
just above the holes.
Recommended min convection
area above the stove : 800 cm²
(may be distributed)
Distance to non-combustible material 0 mm
(10 mm is recommended)
Distance to combustible
material min. 250 mm
Clearance
min. 800 mm
Distance
min. 400 mm
Comentarios a estos manuales